SPECORD 50 PLUS
Entry-level Split Beam UV-Vis with 12,000 nm/min scanning and baseline noise at most 0.0001 A.
SPECORD 50 PLUS spans 190–1100 nm with fixed 1.4 nm slit, ±0.003 A visible photometric accuracy and Split Beam optics.
SPECORD 50 PLUS is Analytik Jena's entry UV-Vis with Split Beam Technology and a single monochromator. A continuously measured reference compensates lamp/electronic drift, supporting baseline noise at most 0.0001 A and long-term stability ±0.0005 A/h.
Its fixed 1.4 nm slit suits most broad solution absorption bands. It scans up to 12,000 nm/min, with 0.001 s minimum integration and 0.02 nm data steps. Photometric range is −3 to 3 A; accuracy is ±0.003 A visible and ±0.010 A UV. Halogen/deuterium lamps switch in a configurable 300–450 nm region, and two uncooled photodiodes detect light. A holmium oxide filter provides internal calibration.
Optional USP/Ph. Eur. validation and 21 CFR Part 11 electronic records are available, as are thermostated cell changers, an integrating sphere and a 116-position autosampler.
| Instrument type | Double-beam UV-Vis spectrophotometer with Split Beam Technology and single monochromator |
|---|---|
| Wavelength range | 190–1100 nm |
| Spectral slit width | Fixed 1.4 nm |
| Wavelength accuracy | ±0.1 nm at 656.1 nm; ±0.5 nm at 360.9 nm using holmium oxide |
| Wavelength repeatability | At most 0.02 nm RMS at 360.9 nm |
| Scan speed | Up to 12,000 nm/min |
| Minimum integration time | 0.001 s; minimum data step 0.02 nm |
| Photometric range | −3 to 3 A; software display −9 to 9 A |
| Measurement modes | Energy, absorbance, transmittance and reflectance |
| Photometric accuracy | ±0.003 A visible; ±0.010 A UV |
| Photometric repeatability | At most 0.0005 |
| Baseline noise at 500 nm | At most 0.0001 A RMS |
| Baseline deviation | ±0.0005 A; long-term stability at 500 nm ±0.0005 A/h |
| Zero transmittance | ±0.05% T |
| Stray light | At most 0.3% T at 198 nm (KCl); 0.03% T at 220/240 nm (NaI); 0.02% T at 340 nm (NaNO₂) |
| Light sources | Halogen and deuterium lamps; adjustable crossover 300–450 nm |
| Detectors | Two uncooled photodiodes |
| Optics | Single monochromator with imaging grating and quartz-coated aspheric optics |
| Internal calibration | Holmium oxide filter |
| Cuvette compartment (W×D×H) | 364 × 185 × 200 mm |
| Accessories | Thermostated 8-/6-position cell changers; dual 2 × 8 dissolution changer; ultramicrocell holder; Peltier accessories; sipper; 116-position APG autosampler; integrating sphere; round-cell and solid-sample holders; variable-angle reflection |
| Software | ASpect UV |
| Pharmacopoeia support | Optional validation modules for USP, Ph. Eur. and Analytik Jena specifications |
| 21 CFR Part 11 | Optional FDA 21 CFR Part 11 module with electronic signatures and audit trail |
| Certification | ISO 9001, CE marking |
| Dimensions (W×D×H) | 590 × 690 × 290 mm |
| Weight | 21 kg |
| Operating conditions | 15–35 °C; relative humidity up to 90% at 30 °C |
| Power | 85–264 V AC, 50–60 Hz |